Quickcal ref13/24/2023 Support new options: 312 (Channel scanner) and 355 (Analog demodulation) Increase the offset value limit in pulse measurement mode -80 dB is not big enough Differential measurement impedance format calculation incorrect sta file is no longer licensed, unit will fail to boot QuickCal fails with 'ArgumentOutOfRangeException' using 1.5m cable and narrow span below 1MHz 85052C with full 2-port cal results in cal GUI with some progress bars hidden ERTA/TSS CableWizard creates BAD cable files upon multiple use Timeout during NA/CAT OSL with >= 4001 points SRC unlock in USB power sensor mode when turning on source, N9912A After resuming from suspend with battery saver OFF, bad data S2p file saving" Error: NullReferenceException Increase the offset value limit in pulse measurement mode -80 dB is not big enough - Mouse usage causes limit line crash can't enter IP addresses in LanConfig screen QuickCal fails with 'ArgumentOutOfRangeException' using 1.5m cable and narrow span below 1MHz - Differential measurement impedance format calculation incorrect #RC QUICKCAL UPDATE SERIAL NUMBER#įix ECal serial number handing to allow 10-digit serial programming IMXLastStand: "Stacked" OSL + Normalize cal issue for Magellan FieldFox firmware revisions are listed by model below. Fixed: File Manager: Scrolling on empty list causes unit to freeze. Fixed: SCPI state file will fail siliently when non-system menu is in the menu history. Fixed: QuickCal fails with 'ArgumentOutOfRangeException' when using 1.5m cable and narrow span below 1MHz. Fixed: After recalling a state, the limit line editor will only display integers for the amplitude. Fixed: QSOLT produces "invalid connector ID" errors when using Type N connectors with the T calkit selected. Fixed Radio standards dial (knob) issue in SA Mode. Fixed zoom trace softkey update issues when in Pulse Measurements mode. Supports Peak and Average power sensor model U2044XA Fixed crashes after repeated Normalization calibrations (known in N9913A). Various bugs fixes for ERTA and Option 330. Averaging reset did not happen after measurement changed. Support for U2043XA Wide Dynamic Range Average power sensor Bug fixes for Invalid Connector ID error during Enhanced Resopnse Cal with certain calibration kits. GPS dongle update due to obsolescence (N9912A and N9923A/AN Only). #RC QUICKCAL UPDATE UPDATE#ĮRTA SCPI command update -> see programming guide. Marker BW Q setting is lost when changing between the 2 Big Marker states (A & B).
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |